CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20182 Cisco Catalyst SD-WAN Controller Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Note: Please adhere to CISA’s guidelines to assess exposure and mitigate risks associated wi
View CSAF Summary ABB became aware of multiple internally discovered vulnerabilities in the WebPro SNMP card PowerValue for the product versions listed as affected in the advisory. Depending upon the vulnerability, an attacker with access to local network who successfully exploited this vulnerability could have - Unauthorized access - Insufficient Session Expiration leading to resource unavailability - Uncontrolled Resource Consumption leading to DOS attack ABB strongly advises customers to upda
View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. The Windows gateway is accessible remotely by default. Unauthenticated attackers can therefore search for PLCs, but the user management of the PLCs prevents the actual access to the PLCs – unless it is disabled The following versions of ABB Automation Builder Gateway for Windows are affected: Automation Builder <2.9.0, 2.9.0 CVSS Vendor Equipment Vulnerabilities v3
CISA and the Group of Seven (G7) international partners—Germany, Canada, France, Italy, Japan, the United Kingdom, and the European Union—have released joint guidance, Software Bill of Materials for AI – Minimum Elements, to help public and private sector stakeholders improve transparency in their artificial intelligence (AI) systems and supply chains. A software bill of materials (SBOM) acts as an “ingredients list” for software that better positions organizations to understand their suppl
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to elevate privileges from user to system, which may then enable the attacker to cause a temporary denial of service, open files, or delete files. The following versions of Fuji Electric Tellus are affected: Tellus 5.0.2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Fuji Electric Fuji Electric Tellus Exposed Dangerous Method or Function Background Critical Infrastructure Sectors: Critical Manufa
View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves publicly reported vulnerability. An attacker who successfully exploited these vulnerabilities could cause a crash, denial-of-service (DoS), or potentially remote code execution. The following versions of ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message Syntax are affected: AC500 V3 PM5xxx 3.9.0, 3.9.0_HF1 CVSS Vendor Equipment Vuln
View CSAF Summary Successful exploitation of these vulnerabilities could allow an authenticated attacker to expose sensitive information or cause a CRLF injection. The following versions of Subnet Solutions PowerSYSTEM Center are affected: PowerSYSTEM Center 2020 <=5.28.x (CVE-2026-35504) PowerSYSTEM Center 2020 >=5.8.x|<=5.28.x (CVE-2026-26289) PowerSYSTEM Center 2020 >=5.11.x|<=5.28.x (CVE-2026-33570) PowerSYSTEM Center 2024 >=6.0.x|<=6.1.x (CVE-2026-26289, CVE-2026-35555
View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. An update is available that resolves these vulnerabilities. An attacker who successfully exploited these vulnerabilities could bypass the user management and read visualization files (CVE-2025-2595), read and write certificates and keys (CVE-2025-41659) or cause a denial-of-service (DoS) (CVE-2025-41691). The following versions of ABB AC500 V3 Multiple Vulnerabilities are affec
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-42208 BerriAI LiteLLM SQL Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities&n
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-6973 Ivanti Endpoint Manager Mobile (EPMM) Improper Input Validation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities establi
View CSAF Summary Successful exploitation of this vulnerability may enable an attacker to access tenant email addresses and associated information in cleartext or cause a denial-of-service condition. The following versions of MAXHUB Pivot client application are affected: MAXHUB Pivot client application CVSS Vendor Equipment Vulnerabilities v3 7.3 MAXHUB MAXHUB Pivot client application Use of a Broken or Risky Cryptographic Algorithm Background Critical Infrastructure Sectors: Info
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-0300 Palo Alto Networks PAN-OS Out-of-bounds Write Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catal
View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that resolves a vulnerability. An attacker who successfully exploited this vulnerability could cause the product to stop. The following versions of ABB B&R Automation Runtime are affected: Automation Runtime <6.5, >=6.5, =R4.93 (CVE-2025-11044, CVE-2025-11044) CVSS Vendor Equipment Vulnerabilities v3 6.8 ABB ABB B&R Automation Runtime Allo
View CSAF Summary Successful exploitation of this vulnerability could allow a standard user to escalate privileges on the host machine. The following versions of Johnson Controls CEM AC2000 are affected: CEM AC2000 12.0 (CVE-2026-21661) CEM AC2000 11.0 (CVE-2026-21661) CEM AC2000 10.6 (CVE-2026-21661) CVSS Vendor Equipment Vulnerabilities v3 8.7 Johnson Controls Inc. Johnson Controls CEM AC2000 Uncontrolled Search Path Element Background Critical Infrastructure Sectors: Critical M