CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-45659 Microsoft SharePoint Server Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements
View CSAF Summary Successful exploitation of these vulnerabilities can allow an attacker to cause unauthorized access and exposure of sensitive information when the unauthenticated attacker accesses credentials stored within firmware or system files. The following versions of Schneider Electric EasyLogic T150 and Saitel DP RTU are affected: EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller <=11.06.30 (CVE-2026-9650) EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit &
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to write files, access unauthorized information, exhaust memory, or crash affected DCMTK client or server processes. The following versions of OFFIS DCMTK Toolkit are affected: DCMTK <=3.7.0 (CVE-2026-50003, CVE-2026-50254, CVE-2026-35505, CVE-2026-52868, CVE-2026-44628) CVSS Vendor Equipment Vulnerabilities v3 9.8 OFFIS OFFIS DCMTK Toolkit Improper Limitation of a Pathname to a Restricted Direct
View CSAF Summary Successful exploitation of these vulnerabilities could allow a local attacker to tamper with or destroy information in the affected product, cause a denial-of-service condition in the affected product, or execute arbitrary code when a specially crafted archive file is decompressed by the 7-Zip component included in MELSOFT Update Manager. The following versions of Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M are affected: MELSOFT Update Manager SW1DND-UDM-M >=1.000A
View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure™ IT Data Center Expert. The EcoStruxure™ IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure. The following versions of Schneider Electric EcoStruxure IT Data Center Expert are affected: EcoStruxure IT Data C
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to gain broad unauthorized access, execute arbitrary commands with root privileges, steal sensitive data, and perform actions on behalf of legitimate users across interconnected systems. The following versions of StoneFly Storage Concentrator are affected: Storage Concentrator <8.0.4.22 (CVE-2026-56415, CVE-2026-55721, CVE-2026-50040) Storage Concentrator Virtual Machine <8.0.4.22 (CVE-2026-56415, CVE-2026-
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to enumerate all user accounts and role assignments on a FUXA SCADA/HMI instance. The following versions of Frangoteam FUXA SCADA/HMI are affected: FUXA SCADA/HMI <=1.3.1 (CVE-2026-13207) CVSS Vendor Equipment Vulnerabilities v3 7.5 Frangoteam Frangoteam FUXA SCADA/HMI Authentication Bypass by Spoofing Background Critical Infrastructure Sectors: Critical Manufacturing, En
View CSAF Summary An update is available that resolves vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to stop or corrupt memory data. The following versions of XZ Utils vulnerability impacting B&R Products are affected: PPC3100 <1.8.1, 1.8.1 (CVE-2025-31115) C50 <1.8.0, 1.8.0 (CVE-2025-31115) C80 <1.8.0, 1.8.0 (CVE-2025-31115) FT50 <1.8.1, 1.8.1 (CVE-2025-31115) MT50 <1.8.1, 1.8.1 (CVE-2
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement. The following versions of Delta Electronics DVP12SE PLC are affected: DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818) CVSS Vendor Equipment Vulnerabilities v3 9.8 Delta Electronics Delta Electronics DVP12SE PLC Missing Authenticati
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48558 SimpleHelp Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executiv
CISA and the Federal Bureau of Investigation (FBI) issued an updated Public Service Announcement (PSA) warning of Russian Intelligence Services (RIS) cyber threat actors targeting commercial messaging applications in ongoing phishing campaigns. This PSA is an update to the March 2026 Russian Intelligence Services Target Commercial Messaging Application Accounts and provides recent tactics, recommended mitigations, and samples of phishing messages.
View CSAF Summary Successful exploitation of these vulnerabilities could could provide an unauthenticated user with complete root-level access and control of the system. The following versions of Daktronics Controller Firmware are affected: VFC-DMP-5000 <v8.117.x.x VFC-DMP-5000 <v9.43.x.x VFC-DMP-5000 <v10.34.x.x DMP-5000 <v10.34.x.x DMP-5000 <v8.117.x.x DMP-5000 <v9.43.x.x DMP-8000 <v10.34.x.x DMP-8000 <v8.117.x.x DMP-8000 <v9.43.x.x CVSS Vendor Equipment Vulnerabilities v3 8.1 Daktro
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. The following versions of Delta Electronics DTM Soft are affected: DTMSoft vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 Delta Electronics Delta Electronics DTM Soft Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities
View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery (SSRF) Background Critical Infrastructure Sectors: Healthcare and Publ
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code and upload malicious files to the affected device. The following versions of H.VIEW HV-500S6 IP Camera are affected: H.VIEW HV-500S6 IP Camera IPCAM_V4.06.88.251229 CVSS Vendor Equipment Vulnerabilities v3 7.2 H.VIEW H.VIEW HV-500S6 IP Camera Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Unrestricted Upload of File with Dang
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths. The following versions of pydicom pynetdicom Library are affected: pynetdicom >=v1.0.0|<v3.0.4 CVSS Vendor Equipment Vulnerabilities v3 9.1 pydicom pydicom pynetdicom Library Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Depl
View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control over system operations and disruption of critical services. The following versio
View CSAF Summary Successful exploitation of this vulnerability may return a response containing the CI Server setting information. The following versions of Yokogawa FAST/TOOLS and CI Server are affected: FAST/TOOLS >=R9.01|<=R10.04 Collaborative Information Server (CI Server) >=R1.01|<=R1.04 CVSS Vendor Equipment Vulnerabilities v3 7.5 Yokogawa Yokogawa FAST/TOOLS and CI Server Cleartext Transmission of Sensitive Information Background Critical Infrastructure Sectors: Critical
View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to disclose information and execute arbitrary code. The following versions of Horner Automation Cscape are affected: Cscape <10.2_SP3 CVSS Vendor Equipment Vulnerabilities v3 7.8 Horner Automation Horner Automation Cscape Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EVoke Systems Charging Station Management System are affected: EVoke CSMS vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 EVoke Systems EVoke Systems Charging Station Management System Missing Authentication for Critical Fu
View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery (SSRF) Background Critical Infrastructure Sectors: Healthcare and Publ
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to write to arbitrary file paths. The following versions of pydicom pynetdicom Library are affected: pynetdicom >=v1.0.0|<v3.0.4 CVSS Vendor Equipment Vulnerabilities v3 9.1 pydicom pydicom pynetdicom Library Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Depl
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-12569 PTC Windchill and FlexPLM Improper Input Validation Vulnerability CVE-2026-20230 Cisco Unified Communications Manager Server-Side Request Forgery (SSRF) Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-
Using SASE in a Modern TIC 3.0 Solution CISA’s guidance, The Journey to Zero Trust – Using Secure Access Service Edge in a Modern TIC 3.0 Solution, details how the Trusted Internet Connections (TIC) 3.0 initiative is helping agencies modernize the way their users connect to applications, data and services. While federal agencies are the target audience, any organization looking to modernize its perimeter-based architectures, advance zero trust adoption, and improve visibility and control across
View CSAF Summary WinCC Certificate Manager insufficiently protects key material that could allow an attacker to extract sensitive information. Siemens has released a new version for SIMATIC WinCC Unified PC Runtime V21 and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens WinCC Certificate Manager are affected: SIMATIC WinCC Unified PC Runtime V16 vers:all/* SIMATIC
View CSAF Summary SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to upgrade to version 9.90 or later. For CP300 device models, devices 7ST85 and 7ST86 are advised to upgrade to version 10.00 or later, while the remaining models should
View CSAF Summary B&R is aware of publicly reported vulnerabilities affecting the Linux kernel versions shipped with the products listed as affected in the advisory. Successful local exploitation of these vulnerabilities could allow an attacker to escalate privileges on the affected system. Public proof-of-concept exploits are available for the vulnerabilities described herein. At the time of publication of this advisory, B&R had no evidence of active exploitation targeting B&R products. The fol
View CSAF Summary Successful exploitation of this vulnerability could allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions. The following versions of ABB Freelance Security Lock are affected: ABB System Version (<=Freelance 2013) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2013 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB Sys
View CSAF Summary Successful exploitation of this vulnerability could allow attackers to manipulate critical device settings and repeatedly disrupt operations, potentially causing a loss of communications to the device. The following versions of Hubbell Aclara Metrum Cellular Web Interface are affected: Aclara Metrum Cellular Web Interface CVSS Vendor Equipment Vulnerabilities v3 7.5 Hubbell Hubbell Aclara Metrum Cellular Web Interface Missing Authentication for Critical Function B
View CSAF Summary OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Products using Ope