View CSAF Summary Ruggedcom Rox contains an input validation vulnerability in the Scheduler functionality that could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Ruggedcom Rox are affected: RUGGEDCOM ROX MX5000 vers:intdot/<2.17.1 RUGGEDCOM ROX MX5000RE vers:intdot/
View CSAF Summary Ruggedcom Rox before v2.17.1 contain multiple third-party vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Ruggedcom Rox are affected: RUGGEDCOM ROX MX5000 vers:intdot/<2.17.1 (CVE-2019-13103, CVE-2019-13104, CVE-2019-13106, CVE-2019-14192, CVE-2019-14193, CVE-2019-14194, CVE-2019-14195, CVE-2019-14196, CVE-2019-14197, CVE-2019-14198, CVE-2019-14199, CVE-2019-14200
View CSAF Summary Simcenter Femap is affected by heap based buffer overflow vulnerability in Datakit library that could be triggered when the application reads files in IPT format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version. The following versions
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code. The following versions of Universal Robots Polyscope 5 are affected: Polyscope 5 <5.25.1 CVSS Vendor Equipment Vulnerabilities v3 9.8 Universal Robots Universal Robots Polyscope 5 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Coun
View CSAF Summary Ruggedcom Rox contains an input validation vulnerability in the feature key installation process that could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Ruggedcom Rox are affected: RUGGEDCOM ROX MX5000 vers:intdot/<2.17.1 RUGGEDCOM ROX MX5000RE vers:intd
View CSAF Summary Siemens Teamcenter is affected by multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Teamcenter are affected: Teamcenter V2312 vers:intdot/<2312.0014, vers:intdot/<2312.0009 (CVE-2026-33862, CVE-2026-33893, CVE-2024-4367) Teamcenter V2406 vers:intdot/<2406.0012,
View CSAF Summary Solid Edge SE2026 before Update 5 is affected by two file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Solid Edge SE2026 and recommends to update to the latest version. The following versions of Siemens Solid Edge are affected: Solid Edge vers:intdot/<226.0.5 CVSS Vendor Equipm
View CSAF Summary The web server in SENTRON 7KT PAC1261 Data Manager Before V2.1.0 contains a request smuggling vulnerability in the Go Project's net/http package that could allow an attacker to retrieve authorization tokens that can be used to gain administrative control over the device. Siemens has released a new version for SENTRON 7KT PAC1261 Data Manager and recommends to update to the latest version. The following versions of Siemens SENTRON 7KT PAC1261 Data Manager are affected: SENTRON
View CSAF Summary Opcenter RDnL is affected by missing authentication in critical function in ‘ActiveMQ Artemis’. An unauthenticated attacker within the adjacent network could use the Core protocol to force a target broker to establish an outbound Core federation connection to an attacker-controlled rogue broker. This could potentially result in availability impacts or message injection into any queue via the rogue broker. Breaking the integrity of a message has a low impact due to missing auto
View CSAF Summary Ruggedcom Rox contains an improper access control vulnerability that could allow an authenticated remote attacker to read arbitrary files with root privileges from the underlying operating system's filesystem. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Ruggedcom Rox are affected: RUGGEDCOM ROX MX5000 vers:intdot/<2.17.1 RUGGEDCOM ROX MX5000RE vers:intdot/<2.17.1 RUGG
View CSAF Summary SIMATIC S7 PLCs contain multiple vulnerabilities in the web server that could allow an attacker to perform cross-site scripting attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIMATIC S7 PLC Web Server are affected: SIMATIC Drive Contr
View CSAF Summary Multiple industrial devices contain a vulnerability that could allow an attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Industrial Devices are affected: IE/PB LINK HA (6GK1411-5BB00) vers:all/* (
View CSAF Summary SIMATIC HMI Unified Comfort Panels before V21.0 are affected by a vulnerability that allows an unauthenticated attacker to access the web browser via the help link. This vulnerability allows an attacker to access the web browser through the Control Panel if it is not protected by the corresponding security mechanisms. This opens the possibility for the attacker to find backdoors, which might lead to unwanted misconfigurations. Siemens has released new versions for the affected
View CSAF Summary The SIPROTEC 5 devices do not use sufficiently random numbers to generate session identifiers. This could facilitate a brute-force attack against a valid session identifier which could allow an unauthenticated remote attacker to hijack a valid user session. The affected session identifiers are only used in a subset of the endpoints that are provided by the affected products. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or no
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20182 Cisco Catalyst SD-WAN Controller Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Note: Please adhere to CISA’s guidelines to assess exposure and mitigate risks associated wi
View CSAF Summary ABB became aware of multiple internally discovered vulnerabilities in the WebPro SNMP card PowerValue for the product versions listed as affected in the advisory. Depending upon the vulnerability, an attacker with access to local network who successfully exploited this vulnerability could have - Unauthorized access - Insufficient Session Expiration leading to resource unavailability - Uncontrolled Resource Consumption leading to DOS attack ABB strongly advises customers to upda
View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. The Windows gateway is accessible remotely by default. Unauthenticated attackers can therefore search for PLCs, but the user management of the PLCs prevents the actual access to the PLCs – unless it is disabled The following versions of ABB Automation Builder Gateway for Windows are affected: Automation Builder <2.9.0, 2.9.0 CVSS Vendor Equipment Vulnerabilities v3
CISA and the Group of Seven (G7) international partners—Germany, Canada, France, Italy, Japan, the United Kingdom, and the European Union—have released joint guidance, Software Bill of Materials for AI – Minimum Elements, to help public and private sector stakeholders improve transparency in their artificial intelligence (AI) systems and supply chains. A software bill of materials (SBOM) acts as an “ingredients list” for software that better positions organizations to understand their suppl
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to elevate privileges from user to system, which may then enable the attacker to cause a temporary denial of service, open files, or delete files. The following versions of Fuji Electric Tellus are affected: Tellus 5.0.2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Fuji Electric Fuji Electric Tellus Exposed Dangerous Method or Function Background Critical Infrastructure Sectors: Critical Manufa
View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves publicly reported vulnerability. An attacker who successfully exploited these vulnerabilities could cause a crash, denial-of-service (DoS), or potentially remote code execution. The following versions of ABB AC500 V3 Stack Buffer Overflow in Cryptographic Message Syntax are affected: AC500 V3 PM5xxx 3.9.0, 3.9.0_HF1 CVSS Vendor Equipment Vuln
View CSAF Summary Successful exploitation of these vulnerabilities could allow an authenticated attacker to expose sensitive information or cause a CRLF injection. The following versions of Subnet Solutions PowerSYSTEM Center are affected: PowerSYSTEM Center 2020 <=5.28.x (CVE-2026-35504) PowerSYSTEM Center 2020 >=5.8.x|<=5.28.x (CVE-2026-26289) PowerSYSTEM Center 2020 >=5.11.x|<=5.28.x (CVE-2026-33570) PowerSYSTEM Center 2024 >=6.0.x|<=6.1.x (CVE-2026-26289, CVE-2026-35555
View CSAF Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. An update is available that resolves these vulnerabilities. An attacker who successfully exploited these vulnerabilities could bypass the user management and read visualization files (CVE-2025-2595), read and write certificates and keys (CVE-2025-41659) or cause a denial-of-service (DoS) (CVE-2025-41691). The following versions of ABB AC500 V3 Multiple Vulnerabilities are affec
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-42208 BerriAI LiteLLM SQL Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities&n
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-6973 Ivanti Endpoint Manager Mobile (EPMM) Improper Input Validation Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities establi
View CSAF Summary Successful exploitation of this vulnerability may enable an attacker to access tenant email addresses and associated information in cleartext or cause a denial-of-service condition. The following versions of MAXHUB Pivot client application are affected: MAXHUB Pivot client application CVSS Vendor Equipment Vulnerabilities v3 7.3 MAXHUB MAXHUB Pivot client application Use of a Broken or Risky Cryptographic Algorithm Background Critical Infrastructure Sectors: Info
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-0300 Palo Alto Networks PAN-OS Out-of-bounds Write Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catal
View CSAF Summary ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that resolves a vulnerability. An attacker who successfully exploited this vulnerability could cause the product to stop. The following versions of ABB B&R Automation Runtime are affected: Automation Runtime <6.5, >=6.5, =R4.93 (CVE-2025-11044, CVE-2025-11044) CVSS Vendor Equipment Vulnerabilities v3 6.8 ABB ABB B&R Automation Runtime Allo
View CSAF Summary Successful exploitation of this vulnerability could allow a standard user to escalate privileges on the host machine. The following versions of Johnson Controls CEM AC2000 are affected: CEM AC2000 12.0 (CVE-2026-21661) CEM AC2000 11.0 (CVE-2026-21661) CEM AC2000 10.6 (CVE-2026-21661) CVSS Vendor Equipment Vulnerabilities v3 8.7 Johnson Controls Inc. Johnson Controls CEM AC2000 Uncontrolled Search Path Element Background Critical Infrastructure Sectors: Critical M